SC300-P SCIENTIFIC OLFACTOMETER WITH EEG CAPABILITIES

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

SC300-P SCIENTIFIC OLFACTOMETER WITH EEG CAPABILITIES :

Scentroid SC300-P (Scientific Olfactometer) is a specialized multi-sensory olfactometer with EEG and FNIR capabilities for advance psychological and physiological research and treatment. The SC300-P has been used by researchers and doctors to research and treat a variety of disorders including Post Traumatic Stress disorder.

Zero Contamination

All mass flow controllers, solenoid valves have 100% stainless steel wetted surfaces. All tubing, nose masks, even table and dividers are also made of stainless steel ensuring no contamination or odour residual.

Dedicated Administrator Station

In the Scentroid SC300-P (Scientific Olfactometer with EEG Capabilities), test administrator can view live results, analyse data, and control the test using the dedicated Admin Station with the Siemens 8” touch screen.

Software Reliability

Scentroid SC300-P (Scientific Olfactometer with EEG Capabilities) uses Siemens industrial PLC with real -time operating system to ensure reliable operation and a seamless integration with EEG and FNIR instruments.

Complete Solution

The Scentroid SC300-P (Scientific Olfactometer with EEG Capabilities) is built into two rugged waterproof Pelican® cases weighing less than 20 Kg each for ease of transportation. There are no additional software or hardware required to conduct full olfactory, visual, and audiotorial psychological or physiological evaluation.

Test Modes

Scentroid SC300-P is loaded with a variety of physiological and psychological test modes such as olfactory/audio psychological evaluation where pulses of odour and visual stimuli are presented in fixed or randomly determined intervals. Other test modes can be easily programmed by the user through the graphical interface.

Multi-Odour Simulation

The SC300-P (Scientific Olfactometer with EEG Capabilities) can load up to 8 odours simultaneously. The odours are pulled automatically into theSC300-P using vacuum rather than pressurization. Ensuring reliable samples that can be created in the laboratory or obtained directly from the environment.

SC300-P Applications

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

SC300-P Applications

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities
  • Olfactory Sensitivity testing
  • PTSD study and treatment
  • Multi-sensory psychological study
  • Diagnostic and treatment of olfactory disorders
  • Product testing and market research

SC300-P Basics of Operation

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities
Scentroid SC300P Scentroid Scentroid

SC300-P Basic of Operation

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities
  • Clean air is supplied by the portable Air Supply Module
  • Up to 8 samples are connected to the sample ports and prepared for presentation
  • Panelists are fitted with EEG cap and the system is set to record response
  • A test mode is selected and audio and visual data loaded for presentation
  • The SC300P will present olfactory, audio, and video stimuli in accordance to the defined test mode
  • At each presentation, the SC300P will trigger the EEG with identification of the audio, video and olfactory stimuli presented allowing easy analysis of subject’s response

SC300-P Capabilities

A complete multisensory olfactometer

SC300-P Capabilities

A complete multisensory olfactometer

The SC300-P (Scientific Olfactometer with EEG Capabilities) is more than just an olfactometer, but a true multisensory stimuli instrument. Up to 8 odours can be connected to the instrument and programmed to be administered to the panellist at various concentrations. Images, videos, and audio stimuli can be simultaneously administered by the SC300-P (Scientific Olfactometer with EEG Capabilities) via its external monitor to provide a complete sensory immersion.

EEG, FNIR, AND EPRIME CONNECTIVITY

The SC300-P (Scientific Olfactometer with EEG Capabilities) seamlessly integrates with EEG and FNIR machines to provide simultaneous stimuli reading from the panellists. Trigger signals will provide clear reference on which stimuli was being administered. EPrime connectivity allows the SC300-P to act as master or as part of a large network of instruments in a comprehensive study.

SC300-P Technical Specification

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities
Model SC300-P
Testing Modes Sensitivity analysis, Audio/Olfactory pulse presentation, Psychological video/olfactory analysis, custom audio/olfactory/ image test mode.
Visual Interface Large 32” touch screen and Siemens industrial 6” touch screen for sensitivity analysis
Audio Interface Built in speakers with Dolby digital surround sound
Olfactory Interface Choice of sniffing port or half-face disposable masks
Dilution Steps Variable
Number of simultaneous odour presentations 4 upgradable to 8
Pres. Flow Rate Variable: 5 lpm to 30 lpm
EEG interface RS232
FNIR interface RS232
EPrime interface RS232. USB, Ethernet optional
Control Hardware Siemens industrial real time controller
Test Administrator interface Siemens industrial 8” full color touch-screen
Display Language English, Chinese, French, German, Turkish and Spanish

Comprehensive library of test modes

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

Comprehensive library of test modes

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

SC300-P (Scientific Olfactometer with EEG Capabilities) can perform a variety of test modes and can be easily programmed to complete custom experiments. Select the stimuli required (odour, audio, video, or image), the duration of each, randomize them, request panellist surveys, and much more to create your own experiment. The flexibility of the SC300-P makes it an ideal solution for any research project.

SC300 Demo Video

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

SCENTROID SC300-P Scientific Olfactometer

Documentation

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

FAQ

Specialized Multi-Sensory Olfactometer with EEG and FNIR Capabilities

How do I load new audio, images or video files

Audio files need to be in MP3 format, images in JPG and video in MP4 and can be loaded directly using the 32″ touch screen. The duration of the audio and video files should be longer than the duration of each presentation set in the test parameters screen

Do you provide EEG instruments as well?

We can provide you a complete package or interface to your existing EEG instrument. We can custom make interface cables to any EEG, fNIR, or other instrument that you need to work with.

Can the odour concentration be varied during the test?

Yes. You can select what odour concentration is used at each presentation. The order, concentration and even duration of each sample is set individually.

Can you customize the instrument for my research?

Yes. We routinely customize all our products based on clients needs. If you need to interface to eye tracker, thermal camera or develop new test modes just let us know. Our extensive R&D department will be happy to help.

Reviews

What our clients says about SC300P

I
had the opportunity to exchange with them on several key issues in the world of “odours” and I found a very high level of professionalism, dynamism and openness in every topic from sampling, measurement, instrumentation and regulation

Odour specialist Environmental Regulator, Australia

Warranty and Services

24 Months Warranty

We are so confident of the reliability of our products that we are glad to offer our clients comprehensive 24 month full warranty.

Phone Support

Our highly professional customer services are here to serve you, for any technical issue reach them easily via phone: 416.479.0078 – Ext215

SME Support

Connecting you to the Subject Matter Experts! Our customer support is unique in that you can talk directly to the designer or programmer of each product.

Live Chat

If you feel more convenient to solve your technical issue via chat, No problem! reach our highly professional customer services through Live Chat.

Local Support

We have developed a vast growing network of distributors and repair facilities. To find your local support please check our distributors map.

Email Support

For any issue you can reach one of our engineers via email for any technical issue. For fast and efficient support simply email support@scentroid.com

Ask For Quote

captcha

please write the text above in the field below

Top Related Products

Vaccum Chamber

PTFE Bag

N-Butanol

SM100